Skip to content
Total Skills UK
← Back to News
Electrical Times•

The electrical integration challenges of pairing BESS with gas CHP

RenewablesRegulationsWiring RegulationsInspection TestingSafetyIndustry NewsCareers
The growing practice of adding lithium iron phosphate battery storage to sites that already run gas combined heat and power reflects a wider shift in UK commercial and industrial energy, where businesses want to manage peak demand charges and stay running through grid disturbances. For electricians, the important point is that the commercial case is usually made on paper, while the technical problems only show up when the site loses its grid connection and has to operate as an island. A synchronous CHP generator and an inverter-based battery behave very differently under fault and transient conditions. Inverters typically contribute only a modest multiple of their rated current during a fault, so a site that relied on the grid's high fault level for fast disconnection may find that protective devices no longer operate within the required times when islanded. Earthing arrangements also need careful thought, because the reference provided by the distribution network operator disappears in island mode, and the neutral and earthing strategy must remain sound whichever sources are connected. These issues tie directly into areas of BS 7671 that many practising electricians have not yet worked with in depth. Amendment 2 to the 18th Edition introduced Chapter 57 on stationary secondary batteries and Chapter 82 on prosumer's electrical installations, while Section 551 has long set out requirements for low voltage generating sets operating in parallel with or as an alternative to the public supply. A designer or installer working on a hybrid site needs to understand how automatic disconnection of supply is achieved under every operating mode, how discrimination between devices is maintained when fault levels change, and how isolation of all sources is provided for safe maintenance. Connection to the network will also bring in Engineering Recommendation G99 requirements, including loss of mains protection settings that must be coordinated across both the CHP and the battery inverters. Where the integration happens at 11 kV, the work moves into high voltage territory with its own competence and authorisation requirements, but the low voltage side still demands a solid grasp of the Wiring Regulations. For trainees and qualified electricians thinking about career direction, this is a good example of where the industry is heading. Multi-source installations combining generation, storage and sometimes solar PV or EV charging are becoming more common, and they reward people who understand system behaviour rather than just individual components. Inspection and testing is a particular concern, because an installation that verifies correctly with the grid connected may not perform the same way on battery or generator alone. Anyone carrying out periodic inspections on these sites needs to account for all supply sources, confirm that warning notices and isolation arrangements are adequate, and recognise when fault loop impedance values under island conditions need further investigation. Building knowledge in battery storage, current Wiring Regulations and inspection and testing provides a strong foundation for working competently on these increasingly complex hybrid systems.

Source

Based on: The electrical integration challenges of pairing BESS with gas CHP

Published by Electrical Times — Read original article